• Glc 4-20mA Analog Signal Isolator 1 Input 2 Output DC Voltage Signal Isolation
  • Glc 4-20mA Analog Signal Isolator 1 Input 2 Output DC Voltage Signal Isolation
  • Glc 4-20mA Analog Signal Isolator 1 Input 2 Output DC Voltage Signal Isolation
  • Glc 4-20mA Analog Signal Isolator 1 Input 2 Output DC Voltage Signal Isolation
  • Glc 4-20mA Analog Signal Isolator 1 Input 2 Output DC Voltage Signal Isolation
  • Glc 4-20mA Analog Signal Isolator 1 Input 2 Output DC Voltage Signal Isolation

Glc 4-20mA Analog Signal Isolator 1 Input 2 Output DC Voltage Signal Isolation

Task: Adjust
Structure: Combination
Mathematical Model: Linear
Signal: Continuous
Function: Automatic Control, Protection, Monitoring, Measurement
Certification: RoHS, ISO: 9001, CE
Samples:
US$ 35/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Manufacturer/Factory, Trading Company
Diamond Member Since 2021

Suppliers with verified business licenses

Anhui, China
Importers and Exporters
The supplier has import and export rights
Self-branded
The supplier has 5 Self-brands, check the Audit Report for more information
Patents Awarded
The supplier had awarded 22 patents, you can check the Audit Report for more information
to see all verified strength labels (28)
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
  • Product size
  • Selection
  • Wiring
  • Company Profile
Overview

Basic Info.

Model NO.
GLC
Condition
New
Customized
Customized
Material
Plastic
Model
Glc Signal Isolator
Input Signal
4-20mA,0-5V,0-10V,1-5V,0-20mA
Output Signal
4-20mA,0-5V,0-10V,1-5V,0-20mA
Channel
1 in 1 out/1 in 2 out/2 in 2
Transport Package
Carton
Specification
200g
Trademark
QIDIAN
Origin
China
HS Code
8543709990
Production Capacity
200pieces/ Day

Product Description

Product Description

<1>. GLC series signal isolated distributor is a high performance product developed by our own company. It can be used for isolation, transmission and distribution of output signals of two-wire, three-wire and four-wire transmitters.
<2>. Precisely isolates and distributes 4~20mA,0~10V standard signals and other non-standard signals.
<3>. It can be used in interference field caused by common ground interference or loop current, signal conversion in case of mismatch between transmitter and subsequent equipment, and signal distribution of transmitter or sensor.

Features

* Plug-in design, easy to install, debug and maintain, is currently the most popular model
*Open debugging at the top
*35mm standard rail installation *Anti-instantaneous surge, strong anti-interference ability


Glc 4-20mA Analog Signal Isolator 1 Input 2 Output DC Voltage Signal Isolation

Product Parameters

Power Supply
Power Supply
DC24V, ±10%
Current Consumption
≤70mA(1 in 2 out,24V power supply, output 20mA);
Input
Input Signal
4-20mA;0-20mA;0-10mA;0-5V;0-10V;1-5V;customized
Distribution Voltage
24V (Max drive current:30A)
Input Impedance
≤50Ω
Output
Output Signal
4-20mA;0-20mA;0-10mA;0-5V;0-10V;1-5V;customized
Output Load Resistance
RL≥10KΩ (output voltage signal)
Other Parameters
Accuracy
0.1%F.S.
Temp Drift
0.005%F.S/ºC (-20ºC~+55ºC)
Respond Time
≤10mS (0~90%) (TYP)
Temperature Drift
0.005%F.S./ºC (-20ºC~+55ºC)
Isolation intensity
1500V AC/1min(between input-ouput-power)
Insulation resistance
≥100MΩ(between input-ouput-power)
Overload capacity
withstand double rating(continous),10 times rating(10s)
Working Temperature
-20ºC~+55ºC
EMC
Complies with GB/T 18268(IEC61326-1)
Applicable Equipment
Current source,2-wires or 3-wires transmitter
Power Supply                                                          
DC24V, ±10% 
Current Consumption
≤70mA(1 in 2 out,24V power supply, output 20mA);

Detailed Photos

Glc 4-20mA Analog Signal Isolator 1 Input 2 Output DC Voltage Signal Isolation
Glc 4-20mA Analog Signal Isolator 1 Input 2 Output DC Voltage Signal Isolation  

Glc 4-20mA Analog Signal Isolator 1 Input 2 Output DC Voltage Signal Isolation

Product size

Glc 4-20mA Analog Signal Isolator 1 Input 2 Output DC Voltage Signal IsolationGlc 4-20mA Analog Signal Isolator 1 Input 2 Output DC Voltage Signal Isolation

Selection

Glc 4-20mA Analog Signal Isolator 1 Input 2 Output DC Voltage Signal Isolation

Wiring

Glc 4-20mA Analog Signal Isolator 1 Input 2 Output DC Voltage Signal Isolation

 

Company Profile

Glc 4-20mA Analog Signal Isolator 1 Input 2 Output DC Voltage Signal Isolation

Glc 4-20mA Analog Signal Isolator 1 Input 2 Output DC Voltage Signal IsolationGlc 4-20mA Analog Signal Isolator 1 Input 2 Output DC Voltage Signal Isolation

FAQ
1.How long will you give me the reply?
we will contact you in 2 hours as soon as we can.

2. Could I get samples?
Yes,we have materials in stock to help you to get the samples as soon as we can.

3.:How about the quality of the magnets?
We have the certification of ISO,CE and ROSH,we could send the certification test of our company to you.

4.How is the price?
As we believe the quality is the most important,we will provide the best quality signal isolator we can with reasonable price.

5. Could you provide me the shortest lead time?
We have materials in our stock,if you really need,you can tell us and we will try our best to satisfy you

.6:Could I visit your factory?
Of course,if you need we will help you to visit our factory.

7:If I have paid,when will you help me to produce?
When we have received the money in our account,we will give you the receipt and arrange to produce immediately.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now