Customization: | Available |
---|---|
Task: | Adjust |
Structure: | Combination |
Still deciding? Get samples of US$ 49/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
<1>. NPEXA-G11 safety barrier transmits thermocouple signals from hazardous area to safe area by isolating transmitting current or voltage signals,and automatically makes temperature compensation for cold end.
<2>. The input, output, and power supply are galvanically isolated from each other.
<3>. This safety barrier is an intelligent product with online self-diagnosis function.
<4>. Customer may set the type and the range of the input or output signals with a handheld programmer we provide.
Explosive-proof grade: [Ex ia Ga]IIC |
||||||||||||||
Input |
||||||||||||||
Input signal |
TC: K,E,S,B,J,T,R,N, WRe3-WRe25, WRe5-WRe26,etc |
|||||||||||||
Output | ||||||||||||||
Output signal |
Current: 0(4)mA~20mA;0mA~10mA; Voltage: 0(1)V~5V;0V~10V; Signal type is customizable, and specified at product label. |
|||||||||||||
Output load capacity |
0(4)mA~20mA: ≤550Ω; 0mA~10mA:≤1.1KΩ; |
|||||||||||||
Output ripple |
< 5mVrms (Load 250Ω) |
|||||||||||||
Other Parameters | ||||||||||||||
Accuracy (at 25ºC±2ºC without temperature compensation) |
|
|||||||||||||
Load capacity |
0(4)mA~20mA: ≤550Ω; 0mA~10mA: ≤1.1kΩ; 0(1)V~5V: ≥1MΩ; 0V~10V: ≥2MΩ; |
|||||||||||||
Response time | ≤1s | |||||||||||||
Temperature drift | 40ppm/ºC | |||||||||||||
Cold junction compensation accuracy | ±1ºC (Preheated for 10 minutes) | |||||||||||||
Cold junction compensation range | -20ºC~+60ºC | |||||||||||||
Full load power consumption | 0.7W (24V DC power supply, single output); 1.3W (24V DC power supply, double output); |
|||||||||||||
Power supply | 18V DC~32V DC (Recommended voltage: 24V DC) | |||||||||||||
Dielectric strength: (1mA leakage current, 1 minute test time) |
≥3000V AC (between Intrinsically safe and Non intrinsically safe); ≥1500V AC (between Non intrinsically safe and Non intrinsically safe); |
|||||||||||||
Insulation resistance | ≥100MΩ (between input-ouput-power) | |||||||||||||
EMC | IEC61326-3 | |||||||||||||
Ambient Conditions |
Operating temperature range: -20~+60ºC | |||||||||||||
Relative humidity: 10%~90%RH (40ºC) | ||||||||||||||
Operating atmosphere pressure: 80~106kPa | ||||||||||||||
Storage and delivery temperature: -40~+80ºC |
Um =250V AC/DC; Between terminal 1 & 2; Uo=8.7V, Io=1mA, Po=3mW
IIC | IIB | IIA | |
Co | 4.69μF | 48.7μF | 998μF |
Lo | 1000mH | 1000mH | 1000mH |
Customer's photos