• M20*1.5 1/2-14NPT G1/2 Thread Signal Protector Device Outdoor Signal Protection Device Series/Parallel Outdoor Field Mounted SPD Units
  • M20*1.5 1/2-14NPT G1/2 Thread Signal Protector Device Outdoor Signal Protection Device Series/Parallel Outdoor Field Mounted SPD Units
  • M20*1.5 1/2-14NPT G1/2 Thread Signal Protector Device Outdoor Signal Protection Device Series/Parallel Outdoor Field Mounted SPD Units
  • M20*1.5 1/2-14NPT G1/2 Thread Signal Protector Device Outdoor Signal Protection Device Series/Parallel Outdoor Field Mounted SPD Units
  • M20*1.5 1/2-14NPT G1/2 Thread Signal Protector Device Outdoor Signal Protection Device Series/Parallel Outdoor Field Mounted SPD Units
  • M20*1.5 1/2-14NPT G1/2 Thread Signal Protector Device Outdoor Signal Protection Device Series/Parallel Outdoor Field Mounted SPD Units

M20*1.5 1/2-14NPT G1/2 Thread Signal Protector Device Outdoor Signal Protection Device Series/Parallel Outdoor Field Mounted SPD Units

Task: Adjust
Structure: Combination
Mathematical Model: Non-Linear
Signal: Discrete
Function: Automatic Control, Protection
Certification: RoHS, CCC, ISO: 9001, CE
Samples:
US$ 35/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
S-FLP
Condition
New
Customized
Customized
Material
PC
Nominal Voltage
24V
Nominal Current
600mA
Total Nominal Discharge Current
20ka
Wiring
2-Wiring 3-Wiring 4-Wiring
DC Maximum Continuous Working Voltage UC
32V
AC Maximum Continuous Working Voltage UC
22.5V
Transport Package
Box
Trademark
QIDIAN
Origin
Anhui China
HS Code
8536200000
Production Capacity
5000 Piece/ Week

Product Description

S-FLP Series & Parallel Signal Surge Protectors
 
Lightning protection in the field of process measurement and control, providing signal protection for field devices such as transmitters, thermal resistances, solenoid valves, flow meters, valve positioners, frequency converters and other instruments. And the surge protection of I/O of control system such as AI, AO, DI, DO, PI of PLC.DCS. Widely used in petroleum, chemical, natural gas, environmental protection, new energy and other industries.

M20*1.5 1/2-14NPT G1/2 Thread Signal Protector Device Outdoor Signal Protection Device Series/Parallel Outdoor Field Mounted SPD UnitsM20*1.5 1/2-14NPT G1/2 Thread Signal Protector Device Outdoor Signal Protection Device Series/Parallel Outdoor Field Mounted SPD UnitsM20*1.5 1/2-14NPT G1/2 Thread Signal Protector Device Outdoor Signal Protection Device Series/Parallel Outdoor Field Mounted SPD Units

M20*1.5 1/2-14NPT G1/2 Thread Signal Protector Device Outdoor Signal Protection Device Series/Parallel Outdoor Field Mounted SPD Units M20*1.5 1/2-14NPT G1/2 Thread Signal Protector Device Outdoor Signal Protection Device Series/Parallel Outdoor Field Mounted SPD Units M20*1.5 1/2-14NPT G1/2 Thread Signal Protector Device Outdoor Signal Protection Device Series/Parallel Outdoor Field Mounted SPD Units


Basic Parameters:
Model S-FLP-2P-24.EX S-FLP-3P-24.EX
Nominal voltage Un 24V 24V
DC upper limit continuous working voltage Uc 32V 32V
AC upper limit continuous working voltage Uc 22.5V 22.5V
Lightning impulse current limp (10/350μs) per line, D1 2KA 2KA
Total nominal discharge current In(8/20 us), C2 20KA 20KA
Each nominal discharge current In(8/20us),C2 10kA 10kA
Protection voltage Up (8/20 us), C2 L-L≤60V/L-PE≤600V L-L≤60V/L-PE≤600V
Frequency fG (100Ω characteristic impedance) 10MHz 10MHz
Response timeTa <1ns <1ns
Explosion-proof certification Ex d ll C T4/T5/T6 Gb Ex d II C T4/T5/T6 Gb
Ex ia II C T4/T5/T6 Ga Ex is II C T4/T5/T6 Ga
Range of working temperature -40°C-+80°C -40°C-+80°C
Thread module M20*1.5  1/2-14NPT m20*1.5  1/2-14NPT
Grounding method Rail grounding/terminal grounding (optional) Rail grounding/terminal grounding (optional)
Connection Terminal Wire Specifications 1.5mm2 250 meters 1.5mm2  250 meters
Shell material 304 Stainless Steel 304 Stainless Steel
Flame retardant grade (UL94) V0 V0
Protection level IP67 IP67
Standard test IEC 61643-21/GB/T 18802.21 IEC 61643-21/GB/T 18802.21

Selection Guide:
Signal Type SPD module Nominal working voltage Un Nominal current  IL Total nominal discharge current In (8/20us), C2 Wiring Type
2/3/4-wire transmitter, thermal resistance, switch value, digital communication RS485/S232/RS422, flowmeter, solenoid valve, etc. S-FLP-2P-24.EX 24V - 20kA 2-wiring
S-FLP-3P-24.EX
24V
- 20kA 3-wiring
S-FLP-4P-24.EX 24V - 20kA 4-wiring
S-FLP-2S-24.EX 24V 600mA 20kA 2-wiring
S-FLP-3S-24.EX 24V 600mA 20kA 3-wiring

Promotions: 

1. All buyers enjoy guaranteed delivery within 3 days.

2. After the buyer uses it, give a good comment. 5% off your next purchase.

3. If the single consumption amount exceeds 1000 US dollars, enjoy priority delivery service.

4. Support customers' private customization services, parameters, appearance, packaging, etc. can be customized according to customer needs.

5. Customers represent our brand products, enjoy price protection and market protection policies, enjoy priority delivery, and private customized services.

After-sales service policy:

1. All buyers enjoy technical services, and professional technicians teach the use of products.

2. During the 2-year warranty period, if the product has quality problems, you can enjoy free maintenance services. If it cannot be repaired, you can replace it with a new one for free.

3. If it is not the quality problem of the product itself, it is due to the customer's use, causing the product to have quality problems, we provide free maintenance services, and the customer needs to bear the round-trip shipping. 

If you have any needs for the product, please contact TOM in time.

Send your message to this supplier

*From:
*To:
avatar Mr. Wong
*Message:

Enter between 20 to 4,000 characters.