24V DC AC RS485/RS232 Modbus Rtd/Tc Signal Input PLC Signal Surge Protective Device for DC Power System Lightning Protection DIN Rail Installation

Anhui Qidian Automation Technology Co., Ltd.
  • Audited Supplier
  • 6 yrs

Contact Supplier

Still deciding? Get samples of $ !
Request Sample

Product Highlights

  • Comprehensive Signal Protection: Protects transmitters, thermal resistances, solenoid valves, flow meters, and PLC/DCS I/O from surges.
  • Intrinsically Safe Certified: Ex iaC II T4/T5/T6 Ga certified for safe operation in hazardous environments.
  • Ultra-Fast Response Time: Response time under 1 nanosecond ensures immediate protection against lightning impulses.
  • DIN Rail Installation: Designed for easy 35mm DIN rail mounting with optional rail or terminal grounding.
  • Multi-Protocol Support: Compatible with RS485, RS232, MODBUS, PROFIBUS-DP, CAN, and various analog/digital signals.
  • Customization Available: Parameters, appearance, and packaging can be customized according to customer needs.
  • RoHS and CE Certified: Meets international safety standards including RoHS, CCC, ISO 9001, and CE.

Product Images of 24V DC AC RS485/RS232 Modbus Rtd/Tc Signal Input PLC Signal Surge Protective Device for DC Power System Lightning Protection DIN Rail Installation

24V DC AC RS485/RS232 Modbus Rtd/Tc Signal Input PLC Signal Surge Protective Device for DC Power System Lightning Protection DIN Rail Installation pictures & photos
24V DC AC RS485/RS232 Modbus Rtd/Tc Signal Input PLC Signal Surge Protective Device for DC Power System Lightning Protection DIN Rail Installation
24V DC AC RS485/RS232 Modbus Rtd/Tc Signal Input PLC Signal Surge Protective Device for DC Power System Lightning Protection DIN Rail Installation pictures & photos
24V DC AC RS485/RS232 Modbus Rtd/Tc Signal Input PLC Signal Surge Protective Device for DC Power System Lightning Protection DIN Rail Installation
24V DC AC RS485/RS232 Modbus Rtd/Tc Signal Input PLC Signal Surge Protective Device for DC Power System Lightning Protection DIN Rail Installation pictures & photos
24V DC AC RS485/RS232 Modbus Rtd/Tc Signal Input PLC Signal Surge Protective Device for DC Power System Lightning Protection DIN Rail Installation
24V DC AC RS485/RS232 Modbus Rtd/Tc Signal Input PLC Signal Surge Protective Device for DC Power System Lightning Protection DIN Rail Installation pictures & photos
24V DC AC RS485/RS232 Modbus Rtd/Tc Signal Input PLC Signal Surge Protective Device for DC Power System Lightning Protection DIN Rail Installation
24V DC AC RS485/RS232 Modbus Rtd/Tc Signal Input PLC Signal Surge Protective Device for DC Power System Lightning Protection DIN Rail Installation pictures & photos
24V DC AC RS485/RS232 Modbus Rtd/Tc Signal Input PLC Signal Surge Protective Device for DC Power System Lightning Protection DIN Rail Installation
24V DC AC RS485/RS232 Modbus Rtd/Tc Signal Input PLC Signal Surge Protective Device for DC Power System Lightning Protection DIN Rail Installation pictures & photos
24V DC AC RS485/RS232 Modbus Rtd/Tc Signal Input PLC Signal Surge Protective Device for DC Power System Lightning Protection DIN Rail Installation
  • 24V DC AC RS485/RS232 Modbus Rtd/Tc Signal Input PLC Signal Surge Protective Device for DC Power System Lightning Protection DIN Rail Installation
    24V DC AC RS485/RS232 Modbus Rtd/Tc Signal Input PLC Signal Surge Protective Device for DC Power System Lightning Protection DIN Rail Installation
  • 24V DC AC RS485/RS232 Modbus Rtd/Tc Signal Input PLC Signal Surge Protective Device for DC Power System Lightning Protection DIN Rail Installation
    24V DC AC RS485/RS232 Modbus Rtd/Tc Signal Input PLC Signal Surge Protective Device for DC Power System Lightning Protection DIN Rail Installation
  • 24V DC AC RS485/RS232 Modbus Rtd/Tc Signal Input PLC Signal Surge Protective Device for DC Power System Lightning Protection DIN Rail Installation
    24V DC AC RS485/RS232 Modbus Rtd/Tc Signal Input PLC Signal Surge Protective Device for DC Power System Lightning Protection DIN Rail Installation
  • 24V DC AC RS485/RS232 Modbus Rtd/Tc Signal Input PLC Signal Surge Protective Device for DC Power System Lightning Protection DIN Rail Installation
    24V DC AC RS485/RS232 Modbus Rtd/Tc Signal Input PLC Signal Surge Protective Device for DC Power System Lightning Protection DIN Rail Installation
  • 24V DC AC RS485/RS232 Modbus Rtd/Tc Signal Input PLC Signal Surge Protective Device for DC Power System Lightning Protection DIN Rail Installation
    24V DC AC RS485/RS232 Modbus Rtd/Tc Signal Input PLC Signal Surge Protective Device for DC Power System Lightning Protection DIN Rail Installation
  • 24V DC AC RS485/RS232 Modbus Rtd/Tc Signal Input PLC Signal Surge Protective Device for DC Power System Lightning Protection DIN Rail Installation
    24V DC AC RS485/RS232 Modbus Rtd/Tc Signal Input PLC Signal Surge Protective Device for DC Power System Lightning Protection DIN Rail Installation

Find Similar Products

Product Description

S-FLS Series Signal Surge Protectors
 
Lightning protection in the field of process measurement and control, providing signal protection for field devices such as transmitters, thermal resistances, solenoid valves, flow meters, valve positioners, frequency converters and other instruments. And the surge protection of I/O of control system such as AI, AO, DI, DO, PI of PLC.DCS. Widely used in petroleum, chemical, natural gas, environmental protection, new energy and other industries.

24V DC AC RS485/RS232 Modbus Rtd/Tc Signal Input PLC Signal Surge Protective Device for DC Power System Lightning Protection DIN Rail Installation24V DC AC RS485/RS232 Modbus Rtd/Tc Signal Input PLC Signal Surge Protective Device for DC Power System Lightning Protection DIN Rail Installation24V DC AC RS485/RS232 Modbus Rtd/Tc Signal Input PLC Signal Surge Protective Device for DC Power System Lightning Protection DIN Rail Installation
24V DC AC RS485/RS232 Modbus Rtd/Tc Signal Input PLC Signal Surge Protective Device for DC Power System Lightning Protection DIN Rail Installation
24V DC AC RS485/RS232 Modbus Rtd/Tc Signal Input PLC Signal Surge Protective Device for DC Power System Lightning Protection DIN Rail Installation
24V DC AC RS485/RS232 Modbus Rtd/Tc Signal Input PLC Signal Surge Protective Device for DC Power System Lightning Protection DIN Rail Installation


Basic Parameters:
Model S-FLS-2-5.EX S-FLS-2-24.EX
Nominal voltage Un 5V 24V
DC upper limit continuous working voltage Uc 6V 32V
AC upper limit continuous working voltage Uc 4V 22.5V
Universal nominal current lL 600ma 600ma
Total lightning impulse current limp(10/350 μs), D1 4KA 4KA
Lightning impulse current limp (10/350μs) per line, D1 2KA 2KA
Total nominal discharge current In(8/20 us), C2 10KA 10KA
Protection voltage Up (8/20 us), C2 L-L≤45V/L-PE≤600V L-L≤60V/L-PE≤600V
Protection voltage Up(1 kV/us), C3 L_L≤15V/L-PE≤600V L-L≤45V/L-PE≤600V
L-L≤45V/L-PE≤600V 100MHz 10MHz
Series impedance 180 180
Response timeTa <1ns <1ns
Intrinsically safe certified circuits Ex iallC T4/T5/T6 Ga Ex iaC II T4/T5/T6 Ga
Range of working temperature -40°C-+80°C -40°C-+80°C
Installation method 35mm DIN rail 35mm DIN rail
Grounding method Rail grounding/terminal grounding (optional) Rail grounding/terminal grounding (optional)
Connection Terminal Wire Specifications 0.2mm2 ~ 2.5mm2 0.2mm2 ~ 2.5mm2
Shell material PC PC
Flame retardant grade (UL94) V0 V0
Protection level IP20 IP20
Standard test IEC 61643-21/GB/T 18802.21 IEC 61643-21/GB/T 18802.21
Selection Guide:
Signal type SPD model Nominal voltage Un Nominal current IL Total nominal discharge current In (8/20us), C2 Wiring system
0(4)-20mA.
0-10V and other analog signals
S-FLS-2-24.EX 24V 600mA 10KA 2-wiring
S-FLS-3-24.EX 24V 600mA 15KA 3-wiring
Thermal resistance, thermocouple
wait for signal
S-FLS-2-5.EX 5V 600mA 10KA 2-wiring
S-FLS-3-5.EX 5V 600mA 15KA 3-wiring
Switch quantity (digital quantity)
wait for signal
S-FLS-2-24.EX 24V 600mA 10KA 2-wiring
S-FLS-3-24.EX 24V 600mA 15KA 3-wiring
RS-485, MODBUS
PRSFIBUS-DP,
CAN and other signals
S-FLS-2-5.EX 5V 600mA 10KA 2-wiring
RS-232 S-FLS-3-24.EX 24V 600mA 15KA 3-wiring
0(4)-20mA.
0~10V and other analog signals
S-FLS-2-24 24V 600mA 10KA 2-wiring
S-FLS-2-24 24V 600mA 15KA 3-wiring
S-FLS-2-24G 24V 600mA 10KA 2-wiring
S-FLS-3-24G 24V 600mA 15KA 3-wiring
Thermocouple, thermal resistance
wait for signal
S-FLS-2-5 5V 600mA 10KA 2-wiring
S-FLS-3-5 5V 600mA 15KA 3-wiring
S-FLS-2-5G 5V 600mA 10KA 2-wiring
S-FLS-3-5G 5V 600mA 15KA 3-wiring
Switch quantity (digital quantity)
wait for signal
S-FLS-2-24 24V 600mA 10KA 2-wiring
S-FLS-3-24 24V 600mA 15KA 3-wiring
S-FLS-2-24G 24V 600mA 10KA 2-wiring
S-FLS-3-24G 24V 600mA 15KA 3-wiring
RS 485, MODBUS.
RPOFIBUS-DP, CAM
wait for signal
S-FLS-2-5 5V 600mA 10KA 2-wiring
S-FLS-2-5G 5V 600mA 10KA 2-wiring
RS-232 S-FLS-3-24 24V 600mA 15KA 3-wiring
S-FLS-3-24G 24V 600mA 15KA 3-wiring
24V meter power supply S-FLS-2-24D 24V 10A 10KA 2-wiring
 

Promotions: 

1. All buyers enjoy guaranteed delivery within 3 days.

2. After the buyer uses it, give a good comment. 5% off your next purchase.

3. If the single consumption amount exceeds 1000 US dollars, enjoy priority delivery service.

4. Support customers' private customization services, parameters, appearance, packaging, etc. can be customized according to customer needs.

5. Customers represent our brand products, enjoy price protection and market protection policies, enjoy priority delivery, and private customized services.

After-sales service policy:

1. All buyers enjoy technical services, and professional technicians teach the use of products.

2. During the 2-year warranty period, if the product has quality problems, you can enjoy free maintenance services. If it cannot be repaired, you can replace it with a new one for free.

3. If it is not the quality problem of the product itself, it is due to the customer's use, causing the product to have quality problems, we provide free maintenance services, and the customer needs to bear the round-trip shipping. 

If you have any needs for the product, please contact TOM in time.

About the Supplier

This supplier has been audited by BV. Verify the report on the official BV website with ID "MIC-ASR239913". Items marked "verified" are certified.

Watch Video
Watch Video
Anhui Qidian Automation Technology Co., Ltd.
Anhui Qidian Automation Technology Co., Ltd.
Anhui Qidian Automation Technology Co., Ltd.
Anhui Qidian Automation Technology Co., Ltd.
Anhui Qidian Automation Technology Co., Ltd.
Anhui Qidian Automation Technology Co., Ltd.
Anhui Qidian Automation Technology Co., Ltd.
Anhui Qidian Automation Technology Co., Ltd.

About Our Factory & Business Background

Address
Building 14, University Science and Technology Park, No. 6, Fengxia Road, , Xiangshan District, Huaibei City, Huaibei, Anhui, China
Terms of Payment
T/T, PayPal, Western Union
International Commercial Terms(Incoterms)
FOB, EXW, CFR, CIF, FAS, FCA
Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
Nearest Port
Shanghai

Our Production Capability & Technical Expertise

Main Products
Pressure Transmitter, Level Transmitter, Pressure Gauge, Pressure Sensor, Current Transducer, Volatge Transducer, Signal Isolator, Intrinsic Safety Barrier, Level Sensor, Ultrasonic Level Meter

Our Industry Experience & Global Business Record

Export Year
2018-01-01
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

What types of signals does this device protect?
It protects 0(4)-20mA, 0-10V analog signals, thermal resistance, thermocouples, digital quantities, RS485, MODBUS, RS232, and other communication protocols.
What is the response time of the surge protector?
The response time is less than 1 nanosecond (<1ns).
Is this product suitable for hazardous environments?
Yes, it is intrinsically safe certified (Ex iaC II T4/T5/T6 Ga) for use in hazardous areas.
What is the warranty period for this device?
The product comes with a 2-year warranty period covering quality problems with free maintenance or replacement.
Can the product parameters be customized?
Yes, we support private customization services for parameters, appearance, and packaging according to customer needs.
How is the product installed?
It is installed on a 35mm DIN rail with options for rail grounding or terminal grounding.
What is the lead time for delivery?
The average lead time is within 15 workdays for both peak and off-peak seasons.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now