• Electrical Safety Barrier Temperature Converter Voltage Signal Input Isolated Safety Barrier
  • Electrical Safety Barrier Temperature Converter Voltage Signal Input Isolated Safety Barrier
  • Electrical Safety Barrier Temperature Converter Voltage Signal Input Isolated Safety Barrier
  • Electrical Safety Barrier Temperature Converter Voltage Signal Input Isolated Safety Barrier
  • Electrical Safety Barrier Temperature Converter Voltage Signal Input Isolated Safety Barrier
  • Electrical Safety Barrier Temperature Converter Voltage Signal Input Isolated Safety Barrier

Electrical Safety Barrier Temperature Converter Voltage Signal Input Isolated Safety Barrier

Task: Adjust
Structure: Combination
Mathematical Model: Linear
Signal: Continuous
Function: Automatic Control, Protection, Monitoring, Measurement
Certification: RoHS, ISO: 9001, CE
Samples:
US$ 88/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Manufacturer/Factory, Trading Company
Diamond Member Since 2021

Suppliers with verified business licenses

Anhui, China
Importers and Exporters
The supplier has import and export rights
Self-branded
The supplier has 5 Self-brands, check the Audit Report for more information
Patents Awarded
The supplier had awarded 22 patents, you can check the Audit Report for more information
to see all verified strength labels (28)
  • Overview
  • Product Description
  • Product Parameters
  • Product size
  • Wiring
  • Installation Instructions
  • Company Profile
Overview

Basic Info.

Model NO.
GM511
Condition
New
Customized
Customized
Material
Plastic
Model
Npexa-C177 Tc Mv Intrinsic Safety Isolated Barrier
Input Signal
Tc Mv Signals
Output Signal
Tc Mv Signal (4~20mA)
Power Supply
18V DC~32V DC
Channel
1 in 1 out;1 in 2 out;2 in 2 out;
Accuracy
0.1%Fs
Response Time
Less 2s
Transport Package
Carton
Specification
200g
Trademark
Qidian
Origin
China
HS Code
8543709990
Production Capacity
200pieces/ Day

Product Description

Product Description

<1>. NPEXA-C177+C171 TC input safety barrier transmits thermocouple millivolt signal from hazardous area to safe area separately output 1:1 millivolt signal and 4mA~20mA current signal. Output millivolt signal is without temperature compensation.

<2>. The input, output, and the power supply ports are galvanically isolated from each other.

<3>. NPEXA-C177+C171 TC input safety barrier is an intelligent product with online self-diagnosis function.


Electrical Safety Barrier Temperature Converter Voltage Signal Input Isolated Safety Barrier

  

Product Parameters

Explosive-proof grade: [Ex ia Ga]IIC

C171

Input signal from hazardous area

TC mV signal: 0mV~100mV

Output signal to safe area

Output 1: 0mV~100mV

Output 2: 4mA~20mA

Output load capacity Output 1: ≥100KΩ
Output 2: ≥350Ω
C177

Input signal from hazardous area

TC mV signal: -5mV~+60mV
Output signal to safe area

1:1 TC mV signal

Output load capacity

≥10KΩ

Other Parameters
Accuracy for RTD (at 25ºC±2ºC,Exciting current no less than 0.5mA)

 

±0.1%FS

Response time ≤2ms
Temperature drift 100ppm/ºC
Power supply 18~32V DC (24V DC)
Dielectric strength: (1mA leakage current, 1 minute test time)

 

≥2500V AC 

Insulation resistance ≥100MΩ (between input-ouput-power)
EMC IEC61000-4

 

Ambient Conditions

Operating temperature range: -20~+60ºC
Relative humidity: 10%~90%RH (40ºC)
Operating atmosphere pressure: 80~106kPa
Storage and delivery temperature: -40~+80ºC

Parameters certified by China National Quality Supervision and Test Centre for Explosion Protected Electrical Products (CQST)

Um =250V AC/DC; Between terminal 1 & 2; Uo=6.5V, Io=1.4mA, Po=2.3mW
 

  IIC IIB IIA
Co 17.5μF 399μF 700μF
Lo 1000mH 1000mH 1000mH

 

Electrical Safety Barrier Temperature Converter Voltage Signal Input Isolated Safety Barrier

   

Product size

Electrical Safety Barrier Temperature Converter Voltage Signal Input Isolated Safety Barrier

 

Wiring

Electrical Safety Barrier Temperature Converter Voltage Signal Input Isolated Safety BarrierElectrical Safety Barrier Temperature Converter Voltage Signal Input Isolated Safety Barrier
Electrical Safety Barrier Temperature Converter Voltage Signal Input Isolated Safety Barrier

Installation Instructions

 

Electrical Safety Barrier Temperature Converter Voltage Signal Input Isolated Safety Barrier

 

Customer's photos
Electrical Safety Barrier Temperature Converter Voltage Signal Input Isolated Safety Barrier

Company Profile

Electrical Safety Barrier Temperature Converter Voltage Signal Input Isolated Safety BarrierElectrical Safety Barrier Temperature Converter Voltage Signal Input Isolated Safety Barrier

FAQ
1.How long will you give me the reply?
we will contact you in 2 hours as soon as we can.

2. Could I get samples?
Yes,we have materials in stock to help you to get the samples as soon as we can.

3.:How about the quality of the magnets?
We have the certification of ISO,CE and ROSH,we could send the certification test of our company to you.

4.How is the price?
As we believe the quality is the most important,we will provide the best quality signal isolator we can with reasonable price.

5. Could you provide me the shortest lead time?
We have materials in our stock,if you really need,you can tell us and we will try our best to satisfy you

.6:Could I visit your factory?
Of course,if you need we will help you to visit our factory.

7:If I have paid,when will you help me to produce?
When we have received the money in our account,we will give you the receipt and arrange to produce immediately.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now