1 in 2 out Switch Input Relay Output Explosion-Proof Isolated Safety Barrier for Signal Isolation

Product Details
Customization: Available
Task: Adjust
Structure: Combination
Still deciding? Get samples of US$ 49/Piece
Request Sample
Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
In-stock Capacity
The supplier has In-stock capacity
Customization from Samples
The supplier provides sample based customization services
Quality Assurance
The supplier provides quality assurance
to see all verified strength labels (28)
  • 1 in 2 out Switch Input Relay Output Explosion-Proof Isolated Safety Barrier for Signal Isolation
  • 1 in 2 out Switch Input Relay Output Explosion-Proof Isolated Safety Barrier for Signal Isolation
  • 1 in 2 out Switch Input Relay Output Explosion-Proof Isolated Safety Barrier for Signal Isolation
  • 1 in 2 out Switch Input Relay Output Explosion-Proof Isolated Safety Barrier for Signal Isolation
  • 1 in 2 out Switch Input Relay Output Explosion-Proof Isolated Safety Barrier for Signal Isolation
  • 1 in 2 out Switch Input Relay Output Explosion-Proof Isolated Safety Barrier for Signal Isolation
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Product size
  • Wiring
  • Company Profile
Overview

Basic Info.

Model NO.
GM511
Mathematical Model
Linear
Signal
Continuous
Function
Automatic Control, Protection, Monitoring, Measurement
Certification
RoHS, ISO: 9001, CE
Condition
New
Customized
Customized
Material
Plastic
Model
G51 Switch Explosion-Proof Safety Barrier
Input Signal
Switch Input
Output Signal
0(4)Ma~20mA;0mA~10mA;0(1)V~5 V;0V~10V
Channel
1 in 1 out;1 in 2 out;2 in 2 out;
Power Supply
18V DC~32V DC
Transport Package
Carton
Specification
200g
Trademark
Qidian
Origin
China
HS Code
8543709990
Production Capacity
200pieces/ Day

Product Description

Product Description

 

<1>. NPEXA-G511 safety barrier transfers digital signals (NAMUR sensors/mechanical contacts) from a hazardous area to safe area, with the relay output or open collector output, free choice to acting or reacting function.

<2>. The input, output, and power supply, 3 terminals are galvanically isolated from each other. 

<3>. It has signal fault self-diagnosis function, and has the advantages of high reliability, quick response and so on. It can be used with all kinds of instruments, DCS and PLC.


1 in 2 out Switch Input Relay Output Explosion-Proof Isolated Safety Barrier for Signal Isolation

Product Parameters

Explosive-proof grade: [Ex ia Ga]IIC

Input

Permissible input signal from hazardous area

Mechanical contacts or NAMUR proximity switch

Switching trigger point Input signal>2.1mA, it is"ON"
Input signal<1.2mA, it is"OFF"
Input resistance 1KΩ
Output
Output signal to safe area Relay contact (Default open)
Relay contact loading (Resistive)

2A/250VAC, 2A/30VDC

Other Parameters
Short-circuit current Approx. 8.5mA
Open-circuit voltage Approx. 8.5V
Line fault detection (LFD) Input current≤80μA, Breakage,output relay opens;
Input current≥6mA, Short-circuit,output relay opens;
Energized/de-energized delay < 20ms
Mechanical life > 10^5 switching cycles
Switching frequency < 10Hz
Full load power consumption ≤ 1.0W
Power supply 18V DC~32V DC (Recommended voltage: 24V DC)
Dielectric strength: (1mA leakage current, 1 minute test time)

≥3000V AC (between Intrinsically safe and Non intrinsically safe);

≥1500V AC (between Non intrinsically safe and Non intrinsically safe);

Insulation resistance ≥100MΩ (between input-ouput-power)
EMC IEC61326-3

 

Ambient Conditions

Operating temperature range: -20~+60ºC
Relative humidity: 10%~90%RH (40ºC)
Operating atmosphere pressure: 80~106kPa
Storage and delivery temperature: -40~+80ºC
  
   

Parameters certified by China National Quality Supervision and Test Centre for Explosion Protected Electrical Products (CQST)

Um =250V AC/DC; Between terminal 1 & 2; Uo=10.5V, Io=11.3mA, Po=29.7mW

  IIC IIB IIA
Co 0.97μF 11μF 52μF
Lo 100mH 300mH 700mH

Product size

1 in 2 out Switch Input Relay Output Explosion-Proof Isolated Safety Barrier for Signal Isolation

 

Wiring

1 in 2 out Switch Input Relay Output Explosion-Proof Isolated Safety Barrier for Signal Isolation

 

1 in 2 out Switch Input Relay Output Explosion-Proof Isolated Safety Barrier for Signal Isolation
Customer's photos
1 in 2 out Switch Input Relay Output Explosion-Proof Isolated Safety Barrier for Signal Isolation

Company Profile

1 in 2 out Switch Input Relay Output Explosion-Proof Isolated Safety Barrier for Signal Isolation1 in 2 out Switch Input Relay Output Explosion-Proof Isolated Safety Barrier for Signal Isolation

FAQ
1.How long will you give me the reply?
we will contact you in 2 hours as soon as we can.

2. Could I get samples?
Yes,we have materials in stock to help you to get the samples as soon as we can.

3.:How about the quality of the magnets?
We have the certification of ISO,CE and ROSH,we could send the certification test of our company to you.

4.How is the price?
As we believe the quality is the most important,we will provide the best quality signal isolator we can with reasonable price.

5. Could you provide me the shortest lead time?
We have materials in our stock,if you really need,you can tell us and we will try our best to satisfy you

.6:Could I visit your factory?
Of course,if you need we will help you to visit our factory.

7:If I have paid,when will you help me to produce?
When we have received the money in our account,we will give you the receipt and arrange to produce immediately.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier