ITEM
|
SPECIFICATIONS
|
|||
Main Input
|
|
Single-phase 200V class: 200V-240V,50Hz/60Hz
|
||
3-phase 400V class: 380V-480V , 50Hz/60Hz
|
||||
Allowable value of change
|
Voltage: 380V-15% ~ 480V+10%; Frequency: ±15%
|
|||
Main output
|
Output voltage
|
Maximum output voltage equals to input voltage
|
||
Output frequency
|
0.5 Hz to 400 Hz
|
|||
Overload capacity
|
150% of rated output current for 60s
200% of rated output current for 2s
|
|||
Control performance
|
Modulation mode
|
3-phase PWM, 2-phase PWM
|
||
|
V/f control for constant torque, V/f control for quadratic load, vector control without PG (open loop control),Energy-saving
|
|||
Setting method of run command
|
Outer terminal, keyboard panel or serial communication
|
|||
Setting method of speed command
|
Analog setting, keyboard, serial communication, UP/DOWN speed setting from external terminal
|
|||
Speed setting resolution
|
Keyboard: 0.1 Hz
Analog setting: 0.05/50Hz (10bit)
|
|||
Speed control precision
|
V/f control: ±2%
vector control without PG (open loop control): ±0.2%
|
|||
Speed control range
|
V/f control 1:40
vector control without PG (open loop control) 1:200
|
|||
Acceleration and Deceleration Time
|
0-3200.0s
|
|||
Switching frequency
|
1.5 kHz ~ 12 kHz, according to junction temperature automatically reduce the switching frequency
|
|||
Environment
|
Standard
|
Development of D31 series frequency inverter follows strict international standards and relevant recommended I EC and EN standards
for control devices, especially IEC/EN61800-5- 1 and IEC/EN61800-3. |
||
Altitude
|
Dreading unnecessary when altitude is 1000m or below (Dreading necessary at altitude higher than 1000m)
|
|||
Ambient environment
|
0.75kW-11kW: Reliable operation at -10 ~ 50°C without debating. When top protective cover is taken off, the environment
temperature can be as high as +50 °C. Above +50 °C, the current drops by 2.2% for each rise of 1 °C in temperature. 15kW-500kW: Reliable operation at -10 - 40®C without dreading. Storage: -25 ~ 70°C |
|||
Humidity
|
No condensed water or drip at 5 ~ 95%, In accordance with IEC60068-2-3
|
|||
Impact strength
|
15gn for continuous 11ms, In accordance with IEC/EN60068- 2-27
|
|||
Maximum antipollution capacity
|
Class 2, in accordance with IEC/EN61800-5-1
|
|||
Structure
|
Protection level
|
Top: IP41 (without removing the protective top cover). Other parts: IP20
|
||
Cooling Method
|
Forced Air cooling
|
|||
FOR MORE PLS CHECK THE USER'S MANUAL...
|