<1>. Working Principle: Open loop direct measurement
<2>. Usage: Used for measuring DC, AC, pulse current and other arbitrary waveform current.
<3>. Advantages: Better cost performance, low power consumption, small volume, light weight, easy installation, perforation input and no insertion loss.
<4>. Application: Frequency conversion speed control system, electric welding machine, electrochemistry, power supply monitoring, electric locomotive, low level starting protection.
<5>. The input, output, power and outer shell are isolated, with strong anti-interference ability and high reliability.
<6>. Full channel configuration, parameter customizable.
Input signal |
0-5A.0-10A.0-50A.0-100A |
Active current |
0 (1) mA ~ 20mA; 0mA ~ 10mA |
Output signal |
4-20mA, 20-4mA.0-10V,Switch quantity, etc. |
Wiring method |
8 mm, 12 mm perforation |
Power supply |
DC24V, DC12V, AC220V |
Accuracy |
0.20% |
Linearity |
0.10% |
Insulation voltage |
3KV / 50HZ, 1 minute |
Output temperature drift |
100ppm / °C |
Full load power consumption |
1W |
Load capacity |
≤500Ω |
Response time |
≤50MS |
Working temperature |
-20 ° C ~ 60 ° C |
Dimensions |
24 * 99 * 65 mm |