Task: Adjust
Structure: Combination
Mathematical Model: Linear
Signal: Continuous
Function: Automatic Control, Protection, Monitoring, Measurement
Certification: RoHS, ISO: 9001, CE
Samples:
US$ 49/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Manufacturer/Factory, Trading Company
Diamond Member Since 2021

Suppliers with verified business licenses

Anhui, China
Importers and Exporters
The supplier has import and export rights
Self-branded
The supplier has 5 Self-brands, check the Audit Report for more information
Patents Awarded
The supplier had awarded 22 patents, you can check the Audit Report for more information
to see all verified strength labels (28)
  • Overview
  • Product Description
  • Product Parameters
  • Product size
  • Wiring
  • Installation Instructions
  • Company Profile
Overview

Basic Info.

Model NO.
NPEXB-GM31
Condition
New
Customized
Customized
Material
Plastic
Model
Npexb-GM31
Input Signal
DC Current Signal
Output Signal
0(4)Ma~20mA;0mA~10mA;0(1)V~5 V;0V~10V
Power Supply
18V DC~32V DC
Transport Package
Carton
Specification
200g
Trademark
Qidian
Origin
China
HS Code
8543709990
Production Capacity
200pieces/ Day

Product Description

Product Description

<1>. NPEXB-GM31 isolated safety barrier transmits current signals from safe area to hazardous area by isolating and transmitting current or voltage signals.

<2>. It can control electric transducer,valve positioner and other field apparatus.

<3>. Input, output and power supply, 3 terminals are galvanically isolated from each other, own the advantages of low power consumption and quick response.


Npexb-GM31 4-20mA Analog Output Safe Barrier with Hart Security Barrier Analog Output Intrinsic Safety Barriers

Product Parameters

Explosive-proof grade: [Ex ia Ga]IIC

Input

Permissible input signal from safe area

DC current signal

Specific type of signal is detailed at product label

Input voltage drop < 1.2V
Output
Output signal to hazardous area Current: 0(4)mA~20mA;     0mA~10mA;
Voltage: 0(1)V~5V;               0V~10V;
Output load capacity

0(4)mA~20mA: ≤800Ω;      0mA~10mA: ≤1.6KΩ;
0(1)V~5V: ≥1MΩ;                0V~10V: ≥2MΩ;

Other Parameters
Accuracy ±0.1%F.S.
Temperature drift <40ppm/ºC
Response time ≤2mS
Power supply 18~32V DC (Recommend 24V DC)
Power consumption 1.0W (24V power supply,20mA single output);
1.7W (24V power supply,20mA double output);
Dielectric strength: (1mA leakage current, 1 minute test time) ≥3000V AC (between Intrinsic safe and Non intrinsic safe)
≥1500V AC (between Non intrinsic safe and Non intrinsic safe)
Insulation resistance ≥100MΩ (between input-ouput-power)
EMC IEC61326-3

 

Ambient Conditions

Operating temperature range: -20~+60ºC
Relative humidity: 10%~90%RH (40ºC)
Operating atmosphere pressure: 80~106kPa
Storage and delivery temperature: -40~+80ºC
  

Parameters certified by China National Quality Supervision and Test Centre for Explosion Protected Electrical Products (CQST)

Um =250V AC/DC; Between terminal 1 & 2, 3 & 4; Uo=28V, Io=93mA, Po=651mW

  IIC IIB IIA
Co 0.087μF 0.68μF 2.27μF
Lo 4mH 12mH 32mH

Npexb-GM31 4-20mA Analog Output Safe Barrier with Hart Security Barrier Analog Output Intrinsic Safety Barriers

   

Product size

Npexb-GM31 4-20mA Analog Output Safe Barrier with Hart Security Barrier Analog Output Intrinsic Safety Barriers

 

Wiring

Npexb-GM31 4-20mA Analog Output Safe Barrier with Hart Security Barrier Analog Output Intrinsic Safety BarriersNpexb-GM31 4-20mA Analog Output Safe Barrier with Hart Security Barrier Analog Output Intrinsic Safety Barriers

Installation Instructions

 

Npexb-GM31 4-20mA Analog Output Safe Barrier with Hart Security Barrier Analog Output Intrinsic Safety Barriers

 

Customer's photos
Npexb-GM31 4-20mA Analog Output Safe Barrier with Hart Security Barrier Analog Output Intrinsic Safety Barriers

Company Profile

Npexb-GM31 4-20mA Analog Output Safe Barrier with Hart Security Barrier Analog Output Intrinsic Safety BarriersNpexb-GM31 4-20mA Analog Output Safe Barrier with Hart Security Barrier Analog Output Intrinsic Safety Barriers

FAQ
1.How long will you give me the reply?
we will contact you in 2 hours as soon as we can.

2. Could I get samples?
Yes,we have materials in stock to help you to get the samples as soon as we can.

3.:How about the quality of the magnets?
We have the certification of ISO,CE and ROSH,we could send the certification test of our company to you.

4.How is the price?
As we believe the quality is the most important,we will provide the best quality signal isolator we can with reasonable price.

5. Could you provide me the shortest lead time?
We have materials in our stock,if you really need,you can tell us and we will try our best to satisfy you

.6:Could I visit your factory?
Of course,if you need we will help you to visit our factory.

7:If I have paid,when will you help me to produce?
When we have received the money in our account,we will give you the receipt and arrange to produce immediately.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now